Related Discussions
How to remove popcorn ceiling with asbestos?

I want to remove my popcorn ceiling, but it has asbestos in it. How do I go about this safely?
How to remove popcorn ceiling with vacuum?

Is there a way to use a vacuum to remove a popcorn ceiling?
How to fix a crack in a door frame?

How to fix a door frame with a split in it?
How to fix squeaky floors under tile?

How to fix squeaky floors under tiles. Don't wish to remove the tile floor first.
How do I kill the power from my main breaker?

I have a home built in 2006, the main panel does not seem to have a main breaker...? See attached pic of the main panel. It's a Siemens G3040 200 amp panel. Outs... See more
Any Ideas for this corner with the wood stove pipe?

I am unclear as to what to do with this part of my house, "The Breakfast Nook".
Electrical problems in my mobile home

Recently one morning I was running my blow dryer when all of a sudden it just stopped dead. (Some of you I am sure can relate to an overheated blow dryer and the fac... See more
Hire an electrician. There are codes and permits involved.
Here is a video regarding codes for romex
https://www.youtube.com/watch?v=Stx8wm8qQvY
George,
What are you running the wire for? There is no one right answer to your question.
a electric range
can 8/3 romex be used on 220 volt
It depends on the amps and kw your stove draws. Under 50 amps and 12kw, 8/3 is appropriate. Over that and you need 6/3. Both require a 240 line with a 2 pole breaker. (In the U.S. 220 and 240 are the same thing.) Your stove is probably a 120/240 load, meaning it needs 2 hots, ground, and neutral. Distance can also come into play if the line will be more than 50 ft. from breaker to appliance. Code requires the 3 wire (actually 4 wires when including the ground), so a 4 wire plug/outlet. Check the manufacturers website for the installation instructions. Romex is a brand name like Kleenex. For most people, it refers to NM-B, non-metalic cable in the 12/2 or 14/2 size used to wire most home needs. We all just call it "Romex." Southwire is the company that makes Romex in all kinds of configurations including the 8/3 you are talking about. Stranded is fine unless the manufacturer calls for solid for some reason. If you are not comfortable wiring inside your electrical box, call an electrician.