Low water pressure only on the hot water side..gas water heater..no visible leaks..unit is 5 years old.
-
KMS Woodworks on Dec 04, 2011Low pressure or low flow? pressure is pretty consistent in most residential applications...flow however can be effected by scale, mineral build ups etc. These usually occur in "constricted" sites like shower heads and faucet aerators. In many cases descaling with a soak in vinegar with improve the flow.Helpful Reply
-
-
Woodbridge Environmental Tiptophouse.com on Dec 05, 2011When you say low water pressure on hot water side. It this at all faucets and tub spouts, or just one faucet in particular? If its only one faucet, then clean the screen on the discharge spout on the faucet. If its all the faucets then check the shut off valve on hot water heater first as it may not be opening all the way. You can also flush it out, but its doubtful that this would cause any real low water issue. Unless some rust floated into the dip tub where the water exits out of the heater and plugged it. Then flushing may help.Helpful Reply
-
-
Transform-A-Door, Inc. on Dec 12, 2011The problem was a malfunctioned "check valve" ThanksHelpful Reply
-
-
KMS Woodworks on Dec 13, 2011A check valve installed between the tank and point of use?....that would be a new one form me.Helpful Reply
-
-
Woodbridge Environmental Tiptophouse.com on Dec 13, 2011What is installed on the top of lots of water heaters, and the first I ever heard failing is a little ball check valve that opens when the water is running through the heater. A spring holds it closed when water is not on. Its reason for being there is to stop convection currents from traveling out of the water heater causing it to turn on and off more during periods of none use. You often see them as blue and pink disks that are fastened right at the heater inlet and outlet where the female coupling is typically installed.Helpful Reply
-
-
KMS Woodworks on Dec 14, 2011cool...learned some new stuff todayHelpful Reply
-
-
Tieger plumbing on Dec 14, 2011Possible mineral deposits / electrolytic action as dissimilar metals come in contact without the use of a dielectric fitting such as a union or insulated nippleHelpful Reply
-
Related Discussions
Old desk with hard rubber top needs help
I have a very old desk that is in great condition except for the top. It is that old, hard rubber and it has a lot of dings and gashes (for lack of a better term). I ... See more
Do colors have to coordinate for bedroom and bathroom?
I recently got overzealous and bought a shower curtain, towels and rug for my bathroom in a totally different color than I planned on doing in the actual bedroom. Doe... See more
Should I remove plaster and lathe or can I just remove plaster?
I have an 1882 Balloon construction house that has some pretty extensive plaster falling off of the lath. I know that the lath actually adds to the wall stability, a... See more
How do I remove sand paint from the walls of a small bathroom?
Thought it was clever and a great look until I realized that if you fall against the wall it would scrape worse than a fall on cement. My husband is elderly and the l... See more
Has anyone had any luck removing artillery fungus?
Please provide personal success stories on how to get rid of fungus in mulch... not links because I have googled and watched others and tried. My daughter had a load ... See more
Which do you prefer: distressed wood or natural wood?
When it comes to choosing wood for your home decor, the finish can make all the difference in achieving the look and feel you want. Distressed wood, with its rugged c... See more
Repurpose glass crackle globes
I have several old solar lights with the glass crackle globe on top. The solar part doesn't work anymore. What could I do with the glass globes?