HVAC question....hi everyone, I hope all is well.
I have to add a vent to our "piano" room (for sake of description). The room is approx 12 x 15 and the existing vent is located on the far outside corner in the wall. The return is in the wall diagonally across the room on an inside wall. The outside wall has 2 windows. Should I add the vent in the floor in front of the window furthest from the existing vent??? If not where.
I have enough room to add a 6 in duct to the main trunk, which is about 18 feet from the area I mentioned.
Help please.
Thanks, Gary
-
Woodbridge Environmental Tiptophouse.com on Dec 13, 2011The duct location should be near the window to wash it with the heat. The return location really has no bearing on where the new duct will go. Just cannot be right next to it. My concern is why are you doing this and what else is located on the duct that your tapping into? If your doing this because the room is to cool in winter, I would look more into sealing the mud sills located below. These areas can loose a lot of heat that is connected to the room above of them. This may be all that is needed to fix your issue. The trunk duct is sized using pressure and volume. When the house was constructed someone figured out just how much air is needed to properly provide the correct amount of heated air and cooled air to keep the room at correct temp. This is true for all the rest of the rooms as well. When someone comes along and taps into the trunk duct and puts another outlet in, then in effect change the entire pressure and volume that is required to produce the air out of all the other grills in the home. Therefor by installing this duct you are in effect removing the pressure from the system and causing the rest of the house to suffer as a result. What people forget to understand, air flow relies on pressure to do the job properly. If you reduce the amount of pressure in the duct trunks, air that would normally flow out of some other perhaps hard to reach locations will diminish and suffer as a result. I find this happening a lot when someone cuts into the trunk duct in the basement when putting in a finished room. To do this properly you need to know the volume that the duct is supposed to handle, to see if its sized to allow for this additional air to flow out. How big is the trunk duct your planning to tap into. Also how big is the rest of each duct that is connected to it as well. What I need to know, is size of duct and amount of taps into that size. Same with each reduction in size until you get to the end. Start at the furnace and work your way out going down the trunk that services the room in question. Also how big is the heating system. BTU's Same with AC how many tons or BTU's is it? Armed with this I can tell you about how bad or well this will work for you.Helpful Reply
-
Related Discussions
Blackout curtains behind vertical blinds
I have two 6' patio doors, and I want to add blackout curtains to keep the sun/cold out. What is the best way to hang them, and what can I use to push the curtains ba... See more
How do I stop the pitting on my stainless steel refrigerator?
I have a 7 month old Frigidaire brand stainless steel refrigerator and I noticed pitting and rust spots numbering somewhere around 30 or 40. Is there something I can... See more
How many solar panels do I need for 1600sq. ft home?
How do I make fall leaf luminaries?
I saw someone making gorgeous luminaries with fall leaves, and I want to give it a try. Do you have any ideas on how to make them?
Where can I find a plastic version of cinder blocks?
I want to decorate my roof garden with benches and shelves, but don't want to invest in the weight.